The Iridex Cyclo G6 glaucoma laser system helps slow glaucoma progression and delays the potential need for surgical Intervention. It features an infrared wavelength laser used to control intraocular pressure (IOP). It is a transscleral treatment where we’re targeting the ciliary processes on the inside of the eye is targeted. The system’s probe is placed directly on the sclera.

The laser system with the MP3 device uses a proprietary MicroPulse™ technology for laser delivery. MicroPulse™ applies the laser for a half millisecond, followed by 1.1 milliseconds of rest, and cycles that thousands of times over a 50-second treatment. Due to the MicroPulse™ technology, other glaucoma treatment methods are still available to the physician, including repeating the MicroPulse™ P3 procedure as necessary.

 


1. MicroPulse-Probe
 

Glaucoma Treatment Stage Primary Open Angle
Repeatable Procedure Yes
MicroPulse™ Technology Yes
Destructive No
SmartProbe Technology Laser Parameter Memory Enabled
Patented Probe Design Curve

Iridex_CycloG6_MP3Probe2.jpg


2. G-Probe
 

Glaucoma Treatment Stage Refractory
Repeatable Procedure Yes
MicroPulse™ Technology No
Destructive Yes
SmartProbe Technology Laser Parameter Memory Enabled
Patented Probe Design Wedge

Iridex_CycloG6_GProbe2.jpg


Application

Wedged tip design of G-Probe supports precise placement around the circumference of the limbus.
 

 

 


Application

The tip design of the MP3 supports a sweeping motion from the 9:30-2:30 and 3:30-8:30 clock positions.
 

 

 



3. G-Probe illuminated

Iridex_CycloG6_GProbe-Illuminate_03.jpg


The illuminated G-probe now allows the targeted treatment of the ciliary body. Transillumination visualizes the ciliary body and thus ensures the exact positioning of the probe. This leads to more consistent results and safer treatment.

 

Iridex_CycloG6_GProbe-Illuminate_01.jpg

Transillumination technique 1

G-Probe Illuminate highlights the anterior margin of the ciliary body (dashed line).

 

Iridex_CycloG6_GProbe-Illuminate_02.jpg

Transillumination technique 2

Use marking pen first to illustrate the anterior margin of the ciliary body as highlighted by transillumination.

 





Micropulse technology finely controls thermal elevation and allows the tissue to cool between laser pulses, minimizing or preventing tissue damage. Treatment risks are reduced or eliminated, with increased patient comfort than with conventional, continuous-wave laser treatment.

Specifications

Wavelength810 nm infrared
Weight3.9 kg (8.5 lb)
Dimensions27 cm x 29.5 cm x 19.7 cm (10.6” W x 11.6” D x 7.8” H)
Connector TypeSmartProbe RFID with Laser Parameter Memory
Electrical
100-240 VAC, 50/60 Hz, <0.8 A
CoolingAir cooled
Exposure Duration CW-Pulse: 10-9000 ms in 549 increments and continuous pulse up to 60 seconds
Exposure IntervalCW-Pulse: 10-3000 ms in 542 increments and One Pulse
MicroPulse Duration MicroPulse: 0.05-1.0 ms in 19 increments
MicroPulse IntervalMicroPulse: 1.0-10.0 ms in 90 increments
MicroPulse Duty Cycle Continuously adjustable from 0.5%-50%, and preset selections of 5%, 10%, and
15% duty cycles
Aiming BeamDiode laser, 635 nm nominal
Treatment Power50-3000 mW, depending on delivery device


Additional features

  • Countdown timer with audible/voice confirmations
  • Programmable user presets for up to 10 individual presets
  • Optional power-adjust wireless footswitch (wired footswitch included)
  • Color LCD Touchscreen interface
  • Backlit control knobs and Treat/Standby button
  • Optional Remote Control (high viewing angle, color LCD Touchscreen)
User Photo

Andreas Zeller

Iridex Cyclo G6

add to inquiry basket

Related products

Surgilum RoboMarker

The RoboMaker from Surgilum is the world’s first self-leveling corneal marker with pre-inked, sterile, disposable tips and an integrated fixation light. These single-use RoboTips are axis-adjustable and place corneal marks within 1…


Iridex IQ 532 / 577

The IQ 532 is a dual port green laser system for comprehensive ophthalmology, usable with MicroPulse for repeatable, tissue-sparing glaucoma and retinal therapies. The IQ 577 is a true yellow laser system for retinal disorders, usable…


slide
slide
slide
slide
slide
slide
slide
slide
slide
slide
slide
slide
slide
slide
slide
slide
slide
slide
slide
slide